* PiFanControlTUI
|
|
Welcome, this project aim to provide a simple minimal intuitive TUI to set your RaspberryPi 5 fan curves.
|
|
|
|
** Install This
|
|
#TODO
|
|
|
|
** Workings
|
|
This project works by setting the following dtparams in =/boot/firmware/config.txt=. Settings require reboot to work.
|
|
#+begin_src txt
|
|
[all]
|
|
dtparam=fan_temp0=55000,fan_temp0_hyst=2000,fan_temp0_speed=90
|
|
dtparam=fan_temp1=65000,fan_temp1_hyst=3000,fan_temp1_speed=160
|
|
dtparam=fan_temp2=70000,fan_temp2_hyst=4000,fan_temp2_speed=200
|
|
dtparam=fan_temp3=72000,fan_temp3_hyst=5000,fan_temp3_speed=255
|
|
#+end_src
|
|
|
|
1. *fan_tempN*: temperature fan activates at in millicelsius
|
|
2. *fan_tempN_hyst*: fan turns off (or to lower setting) when temperature is =fan_tempN - fan_tempN_hyst=. Also in millicelsius
|
|
3. *fan_tempN_speed*: fan speed in range [0, 255] where 255 is 100% fan speed
|
|
|
|
The RaspberryPi 5 firmware supports up to 4 different [[https://github.com/raspberrypi/firmware/blob/4aa2a51fecb99ce16fe591391f6779174b9b5bea/boot/overlays/README#L271][thresholds]].
|
|
The following are the default values used by the firmware:
|
|
#+begin_src txt
|
|
fan_temp0 Temperature threshold (in millicelcius) for
|
|
1st cooling level (default 50000).
|
|
|
|
fan_temp0_hyst Temperature hysteresis (in millicelcius) for
|
|
1st cooling level (default 5000).
|
|
|
|
fan_temp0_speed Fan PWM setting for 1st cooling level (0-255,
|
|
default 75).
|
|
|
|
fan_temp1 Temperature threshold (in millicelcius) for
|
|
2nd cooling level (default 60000).
|
|
|
|
fan_temp1_hyst Temperature hysteresis (in millicelcius) for
|
|
2nd cooling level (default 5000).
|
|
|
|
fan_temp1_speed Fan PWM setting for 2nd cooling level (0-255,
|
|
default 125).
|
|
|
|
fan_temp2 Temperature threshold (in millicelcius) for
|
|
3rd cooling level (default 67500).
|
|
|
|
fan_temp2_hyst Temperature hysteresis (in millicelcius) for
|
|
3rd cooling level (default 5000).
|
|
|
|
fan_temp2_speed Fan PWM setting for 3rd cooling level (0-255,
|
|
default 175).
|
|
|
|
fan_temp3 Temperature threshold (in millicelcius) for
|
|
4th cooling level (default 75000).
|
|
|
|
fan_temp3_hyst Temperature hysteresis (in millicelcius) for
|
|
4th cooling level (default 5000).
|
|
|
|
fan_temp3_speed Fan PWM setting for 4th cooling level (0-255,
|
|
default 250).
|
|
|
|